In analyzing electrical systems, sometimes knowing the numerical value of current is not enough; there is a need to observe harmonics and ripples of current on an oscilloscope (ScopeMeter); the Fluke i200s is specifically designed for this mission.
This product, categorized under digital multimeter accessories and video testing tools, provides its output in voltage (AC coupled mV), unlike the standard i200 model.
The clamp has two selectable working ranges: 20A for higher accuracy at lower currents and 200A for medium-power applications. One of the main advantages of the i200s is its BNC connector, which directly connects to the oscilloscope; however, thanks to the included banana plug adapter, it works easily with any multimeter that has an AC mV range.
The compact design and CAT III 600V safety rating make this probe an ideal option for troubleshooting variable frequency drives (VFDs) and control panels.
Features and Benefits of the Fluke i200s AC Current Clamp
- Two measurement ranges of 20A and 200A for greater flexibility
- Voltage output (mV) for waveform observation on an oscilloscope
- Equipped with a BNC connector and dual banana plug converter for multimeter connection
- Compact and ergonomic design for use in dense environments
- No battery required (powered by electromagnetic induction)
- High stability against environmental noise and electromagnetic interference
Technical Specifications
| Feature | Value / Description |
|---|---|
| Type of Current | AC Current Only |
| Measurement Ranges | 20A and 200A AC |
| Output Signal | 100mV/A (in 20A range) / 10mV/A (in 200A range) |
| Connector Type | BNC (with Dual Banana adapter) |
| Maximum Conductor Diameter | 20mm (0.8 inch) |
| Safety Standard | CAT III 600V |
Frequently Asked Questions about the Fluke i200s AC Current Clamp
What is the main difference between i200 and i200s?
The i200 model has a ‘current’ (mA) output and must be connected to the amp input of a multimeter, whereas the i200s has a ‘voltage’ (mV) output and connects to the voltage input of a multimeter or the input of an oscilloscope.
Is the i200s suitable for power quality troubleshooting?
Yes, due to its capability to connect to an oscilloscope and display waveforms, this probe is very useful for identifying distortions and noise in current.
Does this clamp need periodic calibration?
Like any other precise measuring device, annual calibration is recommended to ensure accuracy in sensitive project results.
Conclusion
The Fluke i200s is a bridge between your multimeter and oscilloscope. If you are looking for a tool that can accompany you in both general electrical work and detailed laboratory analysis, this dual-range Fluke clamp is the best choice.